Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
2.
Sci Total Environ ; 866: 161101, 2023 Mar 25.
Artículo en Inglés | MEDLINE | ID: covidwho-2165830

RESUMEN

Wastewater-based epidemiology during the COVID-19 pandemic has proven useful for public health decision-making but is often hampered by sampling methodology constraints, particularly at the building- or neighborhood-level. Time-weighted composite samples are commonly used; however, autosamplers are expensive and can be affected by intermittent flows in sub-sewershed contexts. In this study, we compared time-weighted composite, grab, and passive sampling via Moore swabs, at four locations across a college campus to understand the utility of passive sampling. After optimizing the methods for sample handling and processing for viral RNA extraction, we quantified SARS-CoV-2 N1 and N2, as well as a fecal strength indicator, PMMoV, by ddRT-PCR and applied tiled amplicon sequencing of the SARS-CoV-2 genome. Passive samples compared favorably with composite samples in our study area: for samples collected concurrently, 42 % of the samples agreed between Moore swab and composite samples and 58 % of the samples were positive for SARS-CoV-2 using Moore swabs while composite samples were below the limit of detection. Variant profiles from Moore swabs showed a shift from variant BA.1 to BA.2, consistent with in-person saliva samples. These data have implications for the broader implementation of sewage surveillance without advanced sampling technologies and for the utilization of passive sampling approaches for other emerging pathogens.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/epidemiología , Aguas del Alcantarillado , Pandemias , Heces
3.
ACS ES T Water ; 2(11): 1944-1952, 2022 Nov 11.
Artículo en Inglés | MEDLINE | ID: covidwho-2115785

RESUMEN

Limited information is available on the decay rate of endogenous SARS-CoV-2 and pepper mild mottle virus (PMMoV) RNA in wastewater and primary settled solids, potentially limiting an understanding of how transit or holding times within wastewater infrastructure might impact RNA measurements and their relationship to community COVID-19 infections. In this study, primary settled solids samples were collected from two wastewater treatment plants in the San Francisco Bay Area. Samples were thoroughly mixed, aliquoted into subsamples, and stored at 4, 22, and 37 °C for 10 days. The concentrations of SARS-CoV-2 (N1 and N2 targets) and PMMoV RNA were measured using an RT-ddPCR. Limited decay (<1 log10 reduction) was observed in the detection of viral RNA targets at all temperature conditions, suggesting that SARS-CoV-2 and PMMoV RNA can be highly persistent in solids. First-order decay rate constants ranged from 0.011 to 0.098 day-1 for SARS-CoV-2 RNA and from 0.010 to 0.091 day-1 for PMMoV RNA depending on the temperature conditions. A slower decay was observed for SARS-CoV-2 RNA in primary settled solids compared to previously reported decay in wastewater influent. Further research is needed to understand if solid content and wastewater characteristics might influence the persistence of viral RNA targets.

4.
J Water Health ; 20(8): 1197-1211, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: covidwho-1938530

RESUMEN

Estimating total infection levels, including unreported and asymptomatic infections, is important for understanding community disease transmission. Wastewater can provide a pooled community sample to estimate total infections that is independent of case reporting biases toward individuals with moderate to severe symptoms and by test-seeking behavior and access. We derive three mechanistic models for estimating community infection levels from wastewater measurements based on a description of the processes that generate SARS-CoV-2 RNA signals in wastewater and accounting for the fecal strength of wastewater through endogenous microbial markers, daily flow, and per-capita wastewater generation estimates. The models are illustrated through two case studies of wastewater data collected during 2020-2021 in Virginia Beach, VA, and Santa Clara County, CA. Median simulated infection levels generally were higher than reported cases, but at times, were lower, suggesting a discrepancy between the reported cases and wastewater data, or inaccurate modeling results. Daily simulated infection estimates showed large ranges, in part due to dependence on highly variable clinical viral fecal shedding data. Overall, the wastewater-based mechanistic models are useful for normalization of wastewater measurements and for understanding wastewater-based surveillance data for public health decision-making but are currently limited by lack of robust SARS-CoV-2 fecal shedding data.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/epidemiología , Heces , Humanos , ARN Viral , Aguas Residuales
5.
ACS ES&T water ; 2022.
Artículo en Inglés | EuropePMC | ID: covidwho-1756021

RESUMEN

Limited information is available on the decay rate of endogenous SARS-CoV-2 and pepper mild mottle virus (PMMoV) RNA in wastewater and primary settled solids, potentially limiting an understanding of how transit or holding times within wastewater infrastructure might impact RNA measurements and their relationship to community COVID-19 infections. In this study, primary settled solids samples were collected from two wastewater treatment plants in the San Francisco Bay Area. Samples were thoroughly mixed, aliquoted into subsamples, and stored at 4, 22, and 37 °C for 10 days. The concentrations of SARS-CoV-2 (N1 and N2 targets) and PMMoV RNA were measured using an RT-ddPCR. Limited decay (<1 log10 reduction) was observed in the detection of viral RNA targets at all temperature conditions, suggesting that SARS-CoV-2 and PMMoV RNA can be highly persistent in solids. First-order decay rate constants ranged from 0.011 to 0.098 day–1 for SARS-CoV-2 RNA and from 0.010 to 0.091 day–1 for PMMoV RNA depending on the temperature conditions. A slower decay was observed for SARS-CoV-2 RNA in primary settled solids compared to previously reported decay in wastewater influent. Further research is needed to understand if solid content and wastewater characteristics might influence the persistence of viral RNA targets. SARS-CoV-2 and PMMoV genomic RNA is highly stable in wastewater settled solids over 10 days at several environmentally relevant temperatures.

6.
Environ Sci Technol ; 55(1): 488-498, 2021 01 05.
Artículo en Inglés | MEDLINE | ID: covidwho-962234

RESUMEN

Wastewater-based epidemiology may be useful for informing public health response to viral diseases like COVID-19 caused by SARS-CoV-2. We quantified SARS-CoV-2 RNA in wastewater influent and primary settled solids in two wastewater treatment plants to inform the preanalytical and analytical approaches and to assess whether influent or solids harbored more viral targets. The primary settled solids samples resulted in higher SARS-CoV-2 detection frequencies than the corresponding influent samples. Likewise, SARS-CoV-2 RNA was more readily detected in solids using one-step digital droplet (dd)RT-PCR than with two-step RT-QPCR and two-step ddRT-PCR, likely owing to reduced inhibition with the one-step ddRT-PCR assay. We subsequently analyzed a longitudinal time series of 89 settled solids samples from a single plant for SARS-CoV-2 RNA as well as coronavirus recovery (bovine coronavirus) and fecal strength (pepper mild mottle virus) controls. SARS-CoV-2 RNA targets N1 and N2 concentrations correlated positively and significantly with COVID-19 clinically confirmed case counts in the sewershed. Together, the results demonstrate that measuring SARS-CoV-2 RNA concentrations in settled solids may be a more sensitive approach than measuring SARS-CoV-2 in influent.


Asunto(s)
COVID-19 , Infecciones por Coronavirus , Animales , Bovinos , Coronaviridae , Humanos , ARN , ARN Viral/genética , SARS-CoV-2 , Aguas Residuales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA